R10H is a residential zoning district governed by ZR 21-14, with residential far of 10, a maximum building height of 215 feet.
These are the figures the engine applies when it models a lot in R10H. Where a rule differs between a narrow and a wide street, both are shown.
| Residential FAR | 10 | ZR 21-14 |
|---|---|---|
| Community facility FAR | 10 | ZR 21-14 |
| Commercial overlay FAR | 2 | ZR 33-121 |
| City of Yes (UAP) maximum FAR | 12 | ZR 27-16 |
| Base minimum — wide street | 60 ft | ZR 21-14 |
|---|---|---|
| Base maximum — wide street | 155 ft | ZR 21-14 |
| Max height — wide street | 215 ft | ZR 21-14 |
| Setback — wide street | 10 ft | ZR 21-14 |
| Base maximum — narrow street | 125 ft | ZR 21-14 |
| Max height — narrow street | 185 ft | ZR 21-14 |
| Setback — narrow street | 15 ft | ZR 21-14 |
| Max height with City of Yes affordability | 235 ft | ZR 23-432 |
| Sky exposure plane begins | 85 ft | ZR 23-432 |
| Front yard | 0 ft | ZR 23-45 |
|---|---|---|
| Side yard | 0 ft | ZR 23-46 |
| Rear yard | 20 ft | ZR 23-47 |
| Lot coverage — interior lot | 80% | |
| Lot coverage — corner lot | 100% |
| Dwelling unit factor | 680 sf per unit | ZR 23-52 |
|---|---|---|
| Minimum lot area, practical | 1,700 sf | |
| Parking spaces per dwelling unit | 0.4 | ZR 25-23 |
| MIH base FAR | 10 | ZR 27-131 |
| MIH maximum FAR where mapped | 12 | ZR 27-131 |
At 10 FAR, a 10,000 square foot lot in R10H carries roughly 100,000 square feet of zoning floor area, which at a 680 square foot dwelling unit factor is about 147 units.
That is the ceiling, not the answer. The height envelope, required yards, lot shape, street width, overlays and any special district all cut into it. Running the real lot is the only way to know which constraint binds first.
A section through the R10H envelope, drawn to scale from the figures in the table above. The solid shape is as of right; where the district carries a City of Yes uplift, the dashed outline is what affordable housing adds.
Diagrammatic. It shows the governing heights and the setback on a regular lot, not your lot: the sky exposure plane, lot shape, corner conditions and any overlay all reshape this in practice.
Every area of the city zoned R10H, from NYC Planning’s published zoning district layer.
Use groups permitted in R10 districts:
Underbuilt here means a lot of at least 2,500 square feet, built to less than half its residential floor area, in private hands, with at least 20,000 square feet of unused capacity. From PLUTO 26v2. How we counted.
R10H has a residential far of 10, set by ZR 21-14. On a 10,000 square foot lot that is about 100,000 square feet of zoning floor area before any bonus, and before the height envelope and yard requirements are applied.
The maximum building height in R10H is 215 feet on a wide street and 185 feet on a narrow street, with a street wall rising to between 60 and 155 feet before a required setback. Height is measured and applied under ZR 21-14.
Yes. Under the Universal Affordability Preference, R10H rises from 10 to 12 where the additional floor area is permanently affordable housing. That is an as-of-right increase, not a discretionary action.
Where MIH is mapped on a lot in R10H, floor area rises from 10 to 12, a gain of 2. MIH applies only where the City has mapped it, so it is a property-by-property question rather than a district-wide one.
Source: NYC Planning zoning districts.